タイトル |
-
en
Measurements of the change of neutronic performance of a hydrogen moderator at Manuel Lujan Neutron Scattering Center due to conversion from ortho- to para-hydrogen state
|
作成者 |
|
アクセス権 |
open access |
主題 |
-
Other
en
Pulsed neutron source
-
Other
en
Hydrogen moderator
-
Other
en
Ortho–para conversion
-
Other
en
Energy spectrum
-
Other
en
Emission time distribution
-
NDC
429.6
|
内容注記 |
-
Abstract
en
The ortho/para-hydrogen ratio is a key parameter for the neutronic performance of a liquid hydrogen moderator. In order to get a better understanding of the influence that the ortho/para-hydrogen ratio has on the performance of such a moderator, we measured the neutronic performance of the partially coupled liquid-hydrogen moderator at the LANSCE Manuel Lujan Jr. Neutron Scattering Center, Los Alamos, USA, as a function of time after condensation. This was done by measuring the energy spectra and pulse shapes (neutron emission time distributions) of this moderator. It was found that the neutronic characteristic of the moderator changes with the elapsed time after condensation, and that the changes were so significant that for any scattering experiment made on such a moderator, the effect should be carefully evaluated.
|
出版者 |
en
Elsevier B.V.
|
日付 |
|
言語 |
|
資源タイプ |
journal article |
出版タイプ |
AM |
資源識別子 |
HDL
http://hdl.handle.net/2115/15820
|
関連 |
-
URI
http://www.sciencedirect.com/science/journal/01689002
-
isVersionOf
DOI
https://doi.org/10.1016/j.nima.2006.06.073
|
収録誌情報 |
-
-
en
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
-
巻566
号2
開始ページ699
終了ページ705
|