  • en Analysis of treatment process time for real-time-image gated-spot-scanning proton-beam therapy (RGPT) system
作成者
アクセス権 metadata only access
権利情報
主題
  • Other en beam-delivery efficiency
  • Other en interplay effect
  • Other en organ motion
  • Other en spot-scanning proton-beam therapy
  • Other en treatment time
  • NDC 492
内容注記
  • Abstract en We developed a synchrotron-based real-time-image gated-spot-scanning proton-beam therapy (RGPT) system and utilized it to clinically operate on moving tumors in the liver, pancreas, lung, and prostate. When the spot-scanning technique is linked to gating, the beam delivery time with gating can increase, compared to that without gating. We aim to clarify whether the total treatment process can be performed within approximately 30 min (the general time per session in several proton therapy facilities), even for gated-spot-scanning proton-beam delivery with implanted fiducial markers. Data from 152 patients, corresponding to 201 treatment plans and 3577 sessions executed from October 2016 to June 2018, were included in this study. To estimate the treatment process time, we utilized data from proton beam delivery logs during the treatment for each patient. We retrieved data, such as the disease site, total target volume, field size at the isocenter, and the number of layers and spots for each field, from the treatment plans. We quantitatively analyzed the treatment process, which includes the patient load (or setup), bone matching, marker matching, beam delivery, patient unload, and equipment setup, using the data obtained from the log data. Among all the cases, 90 patients used the RGPT system (liver: n = 34; pancreas: n = 5; lung: n = 4; and prostate: n = 47). The mean and standard deviation (SD) of the total treatment process time for the RGPT system was 30.3 +/- 7.4 min, while it was 25.9 +/- 7.5 min for those without gating treatment, excluding craniospinal irradiation (CSI; head and neck: n = 16, pediatric: n = 31, others: n = 15); for CSI (n = 11) with two or three isocenters, the process time was 59.9 +/- 13.9 min. Our results demonstrate that spot-scanning proton therapy with a gating function can be achieved in approximately 30-min time slots.
出版者 en John Wiley & Sons
日付
    Issued2020-02
言語
  • eng
資源タイプ journal article
出版タイプ NA
資源識別子 HDL http://hdl.handle.net/2115/76761
関連
  • isIdenticalTo DOI https://doi.org/10.1002/acm2.12804
  • PMID 31886616
収録誌情報
    • EISSN 1526-9914
    • NCID AA12034060
      • en Journal of applied clinical medical physics
      • 21 2 開始ページ38 終了ページ49
コンテンツ更新日時 2023-07-26