一覧に戻る

タイトル
  • en Simple and reliable enumeration of Escherichia coli concentrations in wastewater samples by measuring β-d-glucuronidase (GUS) activities via a microplate reader
作成者
    • en Kikuchi, Kai
    • en Katayose, Yutaka
    • en Tsuda, Shu
    • en Hirano, Reiko
    • en Hirakata, Yuga
    • en Kitajima, Masaaki
    • en Ishii, Satoshi
    • en Hatamoto, Masashi
    • en Takahashi, Masahiro
アクセス権 open access
権利情報
  • en ©2020. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
  • https://creativecommons.org/licenses/by-nc-nd/4.0/
  • en Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
主題
  • Other en Simple enumeration method
  • Other en Fluorogenic enzyme substrate
  • Other en Escherichia coli
  • Other en Sewage wastewater
  • Other en A microplate reader
  • NDC 500
内容注記
  • Abstract en Monitoring of Escherichia coli concentrations at wastewater treatment plants (WWTPs) is important to ensure process performance and protect public health. However, conventional E. coli enumeration methods are complicated and time- and labor-consuming. Here, we report a novel simple and reliable method based on β-D-glucuronidase (GUS) activity assay to enumerate E. coli concentrations in wastewater (WW) samples. An aliquot (20 μL) of the medium with fluorogenic enzyme substrate for E. coli and 180 μL of a WW sample were added to one well of a 96-well microplate. The microplate was placed in a microplate reader at 37°C. To this end, the fluorescence intensity of a fluorogenic enzyme substrate for E. coli was measured every 10 min over 3 h to determine GUS activity. The linear increase in the fluorescence intensity representing the GUS activities showed a positive correlation with E. coli concentrations in wastewater samples. However, the correlation equations were specific to WWTPs, which could be due to the difference in the E. coli population structures among WWTPs. We observed that the wastewater matrix is not a limitation to measure the GUS activity, and a WWTP-specific correlation equation can be used as a calibration curve to estimate the E. coli concentrations in the samples collected from that site. A comparison of the results with those of culture-dependent Colilert method proved that the current method is simple and useful for the enumeration of E. coli concentrations in wastewater samples reliably.
出版者 en Elsevier
日付
    Issued2020-01-25
言語
  • eng
資源タイプ journal article
出版タイプ AM
資源識別子 HDL http://hdl.handle.net/2115/83933
関連
  • isVersionOf DOI https://doi.org/10.1016/j.scitotenv.2020.136928
収録誌情報
    • PISSN 0048-9697
    • NCID AA00836666
      • en Science of The Total Environment
      • 715 開始ページ136928
ファイル
    • fulltext STE136928.pdf
    • 767.17 KB (application/pdf)
      • Issued2020-01-25
コンテンツ更新日時 2023-07-26